Product Details:
Capacity | 200 L |
In an all-in-one heat pump water heater, the heated refrigerant is usually conveyed through a heat exchanger that’s wrapped around the outside of the tank, under the insulation. The refrigerant heats the tank by conduction, transferring heat from the condenser coil through the tank shell, to the water inside.
Heat pump is a device in which the refrigerant R134a is continuously changing the shape from gas to liquid. It pumps out the solar energy from the air in the room and together with electrical energy consumed by compressor it gives out the total heating capacity which is accumulated in the water storage tank. Evaporator is an air-refrigerant heat exchanger. In the evaporator the refrigerant is vaporized at low pressure and relative low temperature. Because of vaporization the heat transfer form air to refrigerant starts. Vaporized refrigerant comes in the compressor where the pressure goes higher and also the temperature. From compressor the vaporized and high temperature steam goes in the condenser (refrigerant-water) where again the heat is transferred from refrigerant to water. The refrigerant is now in liquid shape idler high pressure.
After it flows thought the expansion valve it reaches the basic shape and he
process goes around again. The circuit is in process until the water temperature in the water storage tank reaches the set point
In an all-in-one heat pump water heater, the heated refrigerant is usually conveyed through a heat exchanger that’s wrapped around the outside of the tank, under the insulation. The refrigerant heats the tank by conduction, transferring heat from the condenser coil through the tank shell, to the water inside.
Heat pump is a device in which the refrigerant R134a is continuously changing the shape from gas to liquid. It pumps out the solar energy from the air in the room and together with electrical energy consumed by compressor it gives out the total heating capacity which is accumulated in the water storage tank. Evaporator is an air-refrigerant heat exchanger. In the evaporator the refrigerant is vaporized at low pressure and relative low temperature. Because of vaporization the heat transfer form air to refrigerant starts. Vaporized refrigerant comes in the compressor where the pressure goes higher and also the
temperature. From compressor the vaporized and high temperature steam goes in the condenser (refrigerant-water) where again the heat is transferred from refrigerant to water. The refrigerant is now in liquid shape idler high pressure. After it flows thought the expansion valve it reaches the basic shape and he process goes around again. The circuit is in process until the water temperature in the water storage tank reaches the set point.
Additional Information:
Product Details:
Capacity | 500 L |
Shape | Round |
Material | Glassline Enemel |
In an all-in-one heat pump water heater, the heated refrigerant is usually conveyed through a heat exchanger that’s wrapped around the outside of the tank, under the insulation. The refrigerant heats the tank by conduction, transferring heat from the condenser coil through the tank shell, to the water inside.
Heat pump is a device in which the refrigerant R134a is continuously changing the shape from gas to liquid. It pumps out the solar energy from the air in the room and together with electrical energy consumed by compressor it gives out the total heating capacity which is accumulated in the water storage tank. Evaporator is an air-refrigerant heat exchanger. In the evaporator the refrigerant is vaporized at low pressure and relative low temperature. Because of vaporization the heat transfer form air to refrigerant starts. Vaporized refrigerant comes in the compressor where the pressure goes higher and also the
temperature. From compressor the vaporized and high temperature steam goes in the condenser (refrigerant-water) where again the heat is transferred from refrigerant to water. The refrigerant is now in liquid shape idler high pressure. After it flows thought the expansion valve it reaches the basic shape and he process goes around again. The circuit is in process until the water temperature in the water storage tank reaches the set point.
Product Details:
Capacity | 500 L |
Shape | Tall Unit |
Material | Stainless Steel |
In an all-in-one heat pump water heater, the heated refrigerant is usually conveyed through a heat exchanger that’s wrapped around the outside of the tank, under the insulation. The refrigerant heats the tank by conduction, transferring heat from the condenser coil through the tank shell, to the water inside.
Heat pump is a device in which the refrigerant R134a is continuously changing the shape from gas to liquid. It pumps out the solar energy from the air in the room and together with electrical energy consumed by compressor it gives out the total heating capacity which is accumulated in the water storage tank. Evaporator is an air-refrigerant heat exchanger. In the evaporator the refrigerant is vaporized at low pressure and relative low temperature. Because of vaporization the heat transfer form air to refrigerant starts. Vaporized refrigerant comes in the compressor where the pressure goes higher and also the
temperature. From compressor the vaporized and high temperature steam goes in the condenser (refrigerant-water) where again the heat is transferred from refrigerant to water. The refrigerant is now in liquid shape idler high pressure. After it flows thought the expansion valve it reaches the basic shape and he process goes around again. The circuit is in process until the water temperature in the water storage tank reaches the set point.